Private
Optional
commandPrivate
isPrivate
Readonly
nfcPrivate
Optional
sessionPrivate
Optional
sessionPrivate
Optional
transactionPrivate
aesPrivate
aesPrivate
authenticateContinues a transaction started by a previous authenticateEv2First command. https://www.nxp.com/docs/en/data-sheet/NT4H2421Gx.pdf#page=49&zoom=100,200,154
key slot # to authenticate into
16 byte key data
response code
Private
authenticateChange key slot #1-4. Must be authenticated with key slot #0. https://www.nxp.com/docs/en/data-sheet/NT4H2421Gx.pdf#page=62&zoom=100,200,220
key slot to change where 1<=keySlot<=4
current (16 byte) key data
new (16 byte) key data
response code
Change the access parameters of an existing file. https://www.nxp.com/docs/en/data-sheet/NT4H2421Gx.pdf#page=65&zoom=100,200,220
file to update
see data sheet for input structure
response code
Change key slot #0. Must be authenticated with key slot #0. https://www.nxp.com/docs/en/data-sheet/NT4H2421Gx.pdf#page=62&zoom=100,200,220
updated (16 byte) key data
response code
Get the 7-byte UID from the chip. An authentication with any key slot needs to be performed prior to this function. https://www.nxp.com/docs/en/data-sheet/NT4H2421Gx.pdf#page=61&zoom=100,200,154
response data + response code
Get configuration properties of a specific file. https://www.nxp.com/docs/en/data-sheet/NT4H2421Gx.pdf#page=69&zoom=100,200,606
file to retrieve
response data + response code
Retrieve the current key version of any key. https://www.nxp.com/docs/en/data-sheet/NT4H2421Gx.pdf#page=64&zoom=100,200,154
key slot # to retrieve
response data + response code
Private
incrementRead data from one of the application data files. https://www.nxp.com/docs/en/data-sheet/NT4H2421Gx.pdf#page=73&zoom=100,200,220
file to read from
number of bytes to read
byte at which to start reading
response data + response code
Selects either the PICC level, the application or a file within the application. https://www.nxp.com/docs/en/data-sheet/NT4H2421Gx.pdf#page=77&zoom=100,200,220
file to select
response code
Private
sendWrite data to one of the application data files. https://www.nxp.com/docs/en/data-sheet/NT4H2421Gx.pdf#page=75&zoom=100,200,154
file to write to
data to write
byte at which to begin writing
response code
Initiate an authentication based on standard AES. https://www.nxp.com/docs/en/data-sheet/NT4H2421Gx.pdf#page=46&zoom=100,200,292